CG-1800 OVERVIEW
The CG-1800 master clock generator generates NTSC, PAL and HD Tri-level video clock – as well as word clock through BNC, AES/EBU and S/PDIF outputs – ensuring compatibility with any synchronization system
The CG Series includes three distinct models tailored to different types of studios. The CG-2000 is designed for the needs of broadcasting and post production, the CG-1800 for small to large-scale video/audio synchronization systems, and the CG-1000 for recording studios, live sound applications and professional musicians.
The crystal oscillator is the heart of the clock generator. In each model of the CG Series, an OCXO (oven-controlled crystal oscillator) is used for its high precision, and the fact it is not influenced by the temperature of the environment. Boasting a clock frequency precision of 0.01 ppm*1, which exceeds that of a TCXO (temperature-compensated crystal oscillator), this unit is key in the creation of high-precision synchronization systems - with word output frequency stability of ±0.005ppm or less per day.
The CG-2000 is equipped with an external input connector that supports a 10MHz signal. This allows it to be connected to a rubidium clock or GPS clock for even higher precision.
External clock jitter is reduced using an original TASCAM circuit design that incorporates a high-performance video clock generator engineered with a FPGA*2 and a PLL (phase-locked loop) circuit with a discrete filter. This enables a stable clock signal to be provided to the video/word outputs - improving system stability. The glitch-free relock circuit prevents noise and skipping sounds caused by master clock dropouts.
In addition to (12) word clock outputs and (4) video outputs, the digital outputs include (2) AES3/AES11 and (2) S/PDIF outputs, making this unit useful for large-scale audio/video synchronization systems, and a wide variety of other applications. Of the (12) word outputs, two also support x2Fs, x4Fs and 256Fs output - enabling them to be used in systems with ProTools and other DAW software.
The CG Series has multiple functions to support maintenance, and the identification of issues if problems occur. The analyzer function measures output device termination, input level measurement (for CG-2000 and CG-1800), and the measurement of input frequencies. These built-in features enable the devices to provide troubleshooting support. Additionally, a logging function enables issues to be listed, and saved to a CSV file format on a USB flash drive.
Since crystal oscillators change over time, regular calibration is necessary. In order to avoid possible sync problems, timely inspections – along with regular maintenance is required. The CG Series has a self-correction function, enabling users to conduct maintenance using an external signal input*3 and simple operations.
Amphenol BNC connectors on the chassis use nuts for coupling – making them very durable, Also, a single circuit board is used for each connector - providing excellent resistance to the twisting and pulling of cables, and the suppression of interference between connectors.
The CG Series is the latest in the line of innovative TASCAM professional digital products – engineered with the latest digital clocking technology.
*1 Factory default value
*2 FPGA (Field Programmable Gate Array)
*3 Use of the self-calibration function requires preparation of a separate PPS-output 10MHz oscillator with a built-in GPS antenna.
Lineup
CG-2000 Broadcasting and post production |
CG-1800 Post production |
CG-1000 Music production |
Main features
Abundant Input and Output Connectors Support Use in Large-scale Audio/Video Synchronization Systems | To TOP |
- Numerous output connectors, including 12 word clock outputs
- In addition to (12) word clock outputs and (4) video outputs, the digital outputs include (2) AES3/AES11 and (2) S/PDIF outputs, making this unit useful for large-scale audio/video synchronization systems, and a wide variety of other applications. Of the (12) word outputs, two also support x2Fs, x4Fs and 256Fs output - enabling them to be used in systems with ProTools and other DAW software.
- Supports input and output of a variety of video signal formats - including NTSC, PAL and HD Tri-level
High-precision synchronization systems can be created | To TOP |
- Internal clock uses a high-precision OCXO that is not influenced by the temperature of the environment
-
The crystal oscillator is the heart of the clock generator, In the CG-1800, an OCXO (oven-controlled crystal oscillator) is used for its high precision, and the fact it is not influenced by the temperature of the environment. Boasting a clock frequency precision of 0.01 ppm*, which exceeds that of a TCXO (temperature-compensated crystal oscillator), this unit is key in the creation of high-precision synchronization systems - with word output frequency stability of +/-0.005ppm or less per day.
*factory default value. - Input connector that supports 10MHz signal - allowing the creation of systems with even higher precision
-
An external input connector that supports a 10MHz signal enables the CG-1800 to be connected to a rubidium clock or GPS clock for even higher precision.
Designed for High Reliability and Dependable Stability | To TOP |
- Jitter management circuit provides stable clock
-
External clock jitter is reduced using an original TASCAM circuit design that incorporates a high-performance video clock generator device, featuring an FPGA (Field Programmable Gate Array) and a PLL (phase-locked loop) circuit with a discrete filter. This enables a stable clock signal to be provided to the video/word outputs, improving system stability. - Glitch-free relocking circuit prevents noise and skipping during clock dropouts and recovery
- The CG-1800 constantly measures the external reference clock. In devices that do not have built-in countermeasures, and the master clock signal drops out, the video reference and word clock signals could become out of phase, and sound might skip during the dropout - and again during recovery. In the CG-1800, if the clock drops out, a substitute reference clock signal is maintained with a high-performance holdover. During this time, the video reference and word clock signals are kept in-phase, so restoration of synchronization to the reference signal can occur without glitches - preventing video/audio noise and skipping sounds when recovering from a dropout.
Multiple Functions Support Maintenance and Identification of Issues If Problems Occu | To TOP |
- Analyzer function that can measure output device termination
- In the installation of broadcasting and large-scale post-production studios, numerous connected devices and complicated wiring are common. The CG-1800 has an analyzer function that allows it to measure input frequencies, input levels and the terminations of output devices - enabling it to provide support when troubleshooting problems should they occur.
- Optimal levels can be provided to other devices by adjusting wordclock output levels
- Depending on the routing of wiring and the receiving devices, signal levels could be reduced - resulting in proper reception failures. Since the output of the CG-1800 can be set to multiple levels, it can provide optimal signal levels to connected devices.
- Checking conditions if problems occur is possible through logging
-
One function that enables identification of the causes of trouble is the logging function. In addition to being able to check the log on the CG-1800 display, you can also capture the log as a CSV-format file on a USB flash drive. - Self-calibration function enables maintenance by users
- Since crystal oscillators change over time, regular calibration is necessary. In order to avoid problems that could lead to broadcast trouble, timely inspections and regular maintenance are required. The CG-1800 has a self-correction function, enabling users to conduct maintenance using external signal input* and simple operations.
*Use of the self-calibration function requires preparation of a separate PPS-output 10MHz oscillator with a built-in GPS antenna.
Designed for Durability | To TOP |
- Durable nut-coupling Amphenol BNC connectors
-
Since the Amphenol BNC connectors use nuts for coupling, they are extremely resistant to pulling, twisting and multiple connect-disconnect cycles. - Each connector has an independent circuit board to prevent contact failures due to twisting and repeated use
-
The construction uses a single circuit board for each connector. This provides excellent resistance to the twisting and pulling of cables and suppresses interference between connectors.
Features at a glance | To TOP |
- Internal clock uses a high-precision OCXO (oven-controlled crystal oscillator) that is not influenced by the temperature of the environment
- External input connector that supports 10MHz, allowing creation of systems with even higher precision
- Jitter management circuit provides stable clock
- Glitch-free relocking circuit prevents noise and skipping during clock dropouts and recovery
- Numerous output connectors, including (12) word clock outputs, enabling the use in large-scale video/audio synchronization systems
- Supports input and output of a variety of video signal formats, including NTSC, PAL and HD Tri-level
- AES3 and AES11 signals can also be used for external master clock input sources
- Analyzer function that can measure output device termination
- Optimal levels can be provided to other devices by adjusting wordclock output levels
- Self-calibration function using an external oscillator (Atomic/GPS 10MHz, GPS PPS)
*Use of the self-calibration function requires the use of a separate PPS-output 10MHz oscillator with a built-in GPS antenna. - Word clock performance up to 192 kHz
- 0.1% pull-up/down for 24F(Film) and 29.97F(NTSC), and 4% pull-up/down for 24F(Film) and 25F(PAL)
- Up to (4) system settings can be saved to buttons for recall, and saved settings can be imported and exported via USB
- Durable nut-coupling BNC connectors made by Amphenol
- Independent circuit boards for each connector prevents contact failures due to twisting
- Three-prong IEC power cable included
- Panel-lock switch can be used to prevent inadvertent changes to unit operation
- 128x64-pixel organic EL display with a wide viewing angle
- Firmware updates possible using the USB port
- EIA 1U rack mount size
- RoHS-compliant product